Decentralized control system is a new generation of instrument control system based on microprocessor, which adopts the design principle of decentralized control function, centralized display operation, taking into account division, autonomy and comprehensive coordination. The distributed control system is referred to as DCS, which can also be translated as "decentralized control system" or "distr...
The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring System and the Bentley System 1TM machine management software. TDI combines the capabilities of 3500/20 Framework Interface Modules (RIM) and communication processors such as TDXnet. The TDI runs in the RIM slot of the 3500 frame and is used in conjunction with the M Series monitor (3500/40M, 3500/42M, etc.) to co...
The IC695ALG600 is an analog input module, consisting of 8 analog input channels that account for 16 memory addresses in GEPAC, such as AI1-- AI16, with two addresses assigned to each channel. Each channel has a data type of 16-bit integer and 32-bit floating point, if it is an integer, each channel occupies the previous memory address of each channel, if it is a floating point data, each channel ...
The Framework Interface Module (RIM) is the basic interface of the 3500 framework. It supports Bent's proprietary protocols for framing and retrieving information from the unit. The frame interface module must be placed in the first slot in the frame (next to the power supply). RIM can connect with compatible Bentley communication processors such as TDXnet, TDIX, and DDIX. Although RIM provides so...
Tricon is a highly fault-tolerant programmable logic and process control technology Fault tolerance is the most important feature of TRICON controllers, which can identify transient and steady-state faults online and make appropriate corrections. Fault-tolerant technology improves the safety capability and availability of the controller, so that the process can be controlled continuously. It provi...
The turbine sensor and the preprocessor form an oscillator, and the amplitude of the attenuation is proportional to the distance between the sensor and the measured object as the sensor probe approaches and attenuates. The sensor and preprocessor have been linearly calibrated in complete sets using calibration material 42CrMo4 before delivery, so no calibration is required during installation. The...
1. By continuously comparing the current value of the machine vibration with the alarm value in the configuration, and driving the alarm system, so as to achieve the purpose of protecting the machine; 2.Provide vibration information of critical equipment for operators and maintenance personnel. Through configuration, each channel usually processes the input signal into a "static value". Each...
·Packaging machinery ·Plastic machinery ·Dyeing, printing, and press ·Lifting machinery ·Energy optimization ·Intelligent building ·Marine equipment control ·Wind power generation system ·Municipal pump station ·Air conditioning and refrigeration system ·Municipal engineering Environmental protection engineering ·Steel metallurgy ·Petrochemical industry ·Electric power automation ABB application s...